TILTING TABLES

CLINOMAT

The CLINOMAT is a superior product, with a high standard of reliability offering extremely low life cycle costs. The design of the unit ensures simplicity of operation. During 1997 development in the design and improvement in the main components of the Clinomat, has produced a variable tilt drive giving the user good management and smooth operation of the tilt movement. The table is fitted with a new electronic serial changer with left hand loading for cassettes. Improved power assisted movements complete the Clinomat's upgrade. Standard accessories are: spot film x-ray protection aprons, compression device, patient hand grips, hygienic screen, electronic collimator.

 

Principal Technical Features:

  • Variable speed tilt movement from +90 degrees to -13 degrees Trendelemburg.

  • 500 mm table top (head end) motor driven movement.

  • 480 mm table top (foot end) motor driven movement.

  • Servo assisted screening carriage/serial changer movement.

  • Electromagnetic locks.

  • Automatic serial changer with left hand loading.

  • Wide range of cassette programmes up to 35cm x 35cm.

  • Wide subdivisions possibilities of the x-ray cassettes.

  • No external support needed with image intensifiers up to 9".

Configurations:

CLINOMAT can be supplied combined with the following options upon request:

  • Wide excursion Potter Bucky complete with grid R 1:12 103 L/inch.

  • Motorised four way floating table top.

  • Electronic Collimation ensuring that the x-ray beam is always focused on the aerea of interest.

  • STATIX: Statix column tube support providing coverage of the table as well as offering the capability to carry out examinations in conjunction with a Vertical Bucky stand. The Statix is floor mounted without wall or ceiling fixings. The column rotates through 270 degrees around the vertical axis allowing the overcouch x-ray tube to be parked safely during examinations using the undercouch x-ray tube.

A more low cost version of CLINOMAT 2000V is available. CLINOMAT ECO 2000 main features differs from the standard version in the following:

  • Electromechanical spot film device

  • Up to 4 subdivisions of the x-ray cassettes

  • No electronic collimation

  • No rapid exposure sequence

This version is important expecially when the budget is very low and the need to have a system with simplified

maintenance is necessary.

CLINOMAT BS

90/15 Radiography Fluoroscopy tilting table provided with spot film device, left hand loading; 2x  3x 4x subdivisions of the x-ray cassettes.

Shoulder rest and two hand-grips included.  Grid R:10  103 L/inch.

Suitable for installation of Image Intensifier up to 9” without ceiling fixing.

To be linked with a 16° target Angle x-ray tube such as X 50 H.

Motorized adjustable table-top for longitudinal setting. Motorized collimator, manual setting.

  • Potter bucky and grid R 12  103L/inch provided with under-table excursion device

  • STATIX : column tube stand on floor rails, 180 degrees rotation, without luminous collimator (one collimator to be added)

New model provided with progressive tilting movement and motorized horizontal movement of the spot film / x-ray tube group.

 
Petrakis Holdings Ltd: 18 Lysimachou, Ayia Fyla 3117, P.O.Box: 53430, Limassol 3302, Cyprus.