STEAM STERILIZER HS-4085S

Feature

The sterilizer is equipped with a practical size of rectangular or cylindrical sterilizing chamber. The sterilizing process is most efficient because the materials are sterilized and dreed by air femobal with the pre-vacuum and post vacuum. In particular, the sterilizer with a double door style prevents recontamination by retrieving processed materials to the clean room.

1. CONTROLS

The Control System with a built- in microprocessor, controls process of the cycle, the function of display of a large 5"LCD showing the operating conditions of the sterilizer, the self-diagnosis which detects abnormality and takes necessaly actions and printing which prints out cycle performance records automatically.

2. CYCLE PROGRAM

- The Basic Cycles are programs generally used for most materials to be sterilized.

- The Test Cycles are a Bowie-Dick and a Vacuum Leak Rate Test for chamber.

- The user cycle program can be used and saved by changing the temperature, pressure, exposue time and dry time from the basic cycle programs at the discretion of operator.

3. BOWIE-DICK TEST PROGRAM

This program provides a test for air residual in the chamber after air removal by the vacuum system. If this program detects any residual of air, the wrapped materials shall mot be processed with the vacuum cycle program.

4. LEAK TEST PROGRAM

The leak test program, designed for test of any leakage out of the chamber, shall be performed prior to vacuum sterilization cycle once everyday. If any leakage is detected throughout the test, the vacuum sterilization cycle would not operate

5. AIR FILTER

The bacteria-retentive filter which can filter out 99.97% of 0.3µm particles filters outside air supplied into the chamber during the vent and drying the vent and drying phase. If prevents sterilized items from recontamination by bacteria in the air.

6. VACUUM SYSTEM

The vacuum system with the water pump and ejector is an equipment used for exhausting air or vapor out of the chamber. If enhances sterilization and drying effect with a strong vacuum force and minimizes noise and malfunction.

7. DOOR INTERLOCK

For safety, the chamber door would not open when the power is turned off, the cycle would not operate when the door is open and the door would not open when any pressure exists in the chamber. In a case of the double door style, both of doors would not open simultaneously and one of the doors would open only the other one is locked.

8. SELF-DIAGNOSIS

Seif-diagnosis, detecting 12 types of error, generates alarm and automatically takes any necessary actions.

9. PRINTER

It prints a cycle performance record which reviews, analyzes and saves sterilization results related to management. This document includes sterilizer number, date and yeat, setting value(sterilization temperature, condition temperature, exposure time, and drying time), performance data of each phase (start and finish time, temperature and pressure), maximum/minimum temperature and pressure, elapse time of each phases, acceptance or unacceptance of the cycle and other data (cycle time, cycle number, error codes, power failure/recovery time).


Specification:

Cabinet
Chamber


Operating Temperature
Air Removal
Power Source



Steam Source
Controls
Water Source
Vacuum System
Loading System
Printer
Display
Net Weight

W800×H 1,600×D 892mm
Stainless Steel , Cylindrical Type w/ Jacket ,85.4 Liter cap.
ø400×D680(mm)
100°C ~ 135°C
Vacuum/Gravity
Built-in Steam Generator and External Steam System
AC220V, 3ph, 3wire,50/60Hz or AC380V, 3ph, 4wire,50/60Hz
Optional : External Steam System
Steam Generator :Heater 9kW
8bit Microprocessor
Pressure: 2 kgf/cm² ~ 5 kgf/cm²
Water Ejector
Shelves : 3 set, Rack : 1 set
Dot Matrix, 40 Columns
Dots Graphic Display, LCD
255kg

 